MES Commercial air source heat pump for 50ºC hot water
This is air source circulation type heat pump for commercial hot water rated temperature 50ºC,
Adjustment range from 28ºC to 60ºC, we have the unique design with world famous brand of components, with the testing by our engineer with 15 years experiences, we can ensure the best performance for you.
Product Info.
Additional Info.
WHY US?
Components brands we use:
BEST DESIGN FOR BEST OPERATION!
PRODUCT FEATURES:
a. Copeland and R410a refrigerant for best operation.
b. Stainless steel 304 material for all fasterners, frame of evaporator and etc..
c. Low noise fan motor with metal fan blades, Durable and reliable.
d. World famous brands of components, such as Saginomiya electronic expansion valves, SHF 4-way valves and etc.,
e. With compelete testing in laboratory for good quality and highest COP.
f. All copper material for water pipes.
g. Strong wooden case packing for safe sea transporation.
h. Advanced control system for reaching all of your requirements, such as Rs485, PC connection, Modbus port.
i. Unique cabinet designing, for your better marketing.
Parameters table:
Welcome to MES!
This is air source circulation type heat pump for commercial hot water rated temperature 50ºC,
Adjustment range from 28ºC to 60ºC, we have the unique design with world famous brand of components, with the testing by our engineer with 15 years experiences, we can ensure the best performance for you.
Product Info.
Compressor | Copeland scroll or Panasonic scroll |
Capacity | 12KW, 19KW,25KW, 35KW, 50KW, 65KW, 75KW, 85KW, 105KW, 125KW, 165KW |
Refrigerant | R410A |
Condenser | "ND" Shell & Coil heat exchanger |
Evaporator | Finned tube heat exchanger(High quality, stainless steel 304 for frame) |
Fan motor | Axial |
Fan blades | Metal |
AC contactor & Relay | Schneider |
Electronic expansion valve | Japan Saginomiya or World No.1 Sanhua |
Reversing valve | World No.1 Sanhua |
Controller | LCD |
Package | Wooden case or Carton |
Fasteners | Stainless steel 304 |
Additional Info.
Delivery time | 25 days after order confirmed |
Warranty time | 24 months after shipment |
Payment term | T/T or L/C at sight |
Production capacity | 400 units per month |
Brand | MES or OEM |
WHY US?
Components brands we use:
BEST DESIGN FOR BEST OPERATION!
PRODUCT FEATURES:
a. Copeland and R410a refrigerant for best operation.
b. Stainless steel 304 material for all fasterners, frame of evaporator and etc..
c. Low noise fan motor with metal fan blades, Durable and reliable.
d. World famous brands of components, such as Saginomiya electronic expansion valves, SHF 4-way valves and etc.,
e. With compelete testing in laboratory for good quality and highest COP.
f. All copper material for water pipes.
g. Strong wooden case packing for safe sea transporation.
h. Advanced control system for reaching all of your requirements, such as Rs485, PC connection, Modbus port.
i. Unique cabinet designing, for your better marketing.
Parameters table:
BG12s-N3 | BG19s-N5 | BG12-N3 | BG19-N5 | BG25-N5 | BG35-N10 | BG50-N10 | BG65-N10 | BG75-N20 | BG85-N20 | BG105-N20 | BG125-N20 | BG165-N40 | |||
Rated heating capacity | kW | 12 | 19 | 12 | 19 | 25 | 35 | 50 | 65 | 75 | 85 | 105 | 125 | 165 | |
Rated input power | kW | 2.72 | 4.29 | 2.71 | 4.28 | 5.64 | 7.92 | 11.36 | 14.73 | 16.89 | 19.19 | 23.70 | 28.28 | 37.33 | |
Rated input current | A | 11.88 | 18.73 | 4.94 | 7.79 | 10.27 | 14.41 | 20.68 | 27.83 | 30.74 | 34.92 | 43.14 | 51.47 | 67.94 | |
Maximum input power | kW | 3.54 | 5.58 | 3.53 | 5.56 | 7.34 | 10.29 | 14.77 | 18.85 | 21.96 | 24.94 | 30.81 | 36.76 | 48.53 | |
Maximum input current | A | 15.45 | 24.35 | 6.67 | 10.51 | 13.87 | 19.46 | 27.92 | 35.80 | 41.50 | 47.14 | 58.24 | 69.49 | 91.72 | |
Performance coefficient(COP) | / | 4.41 | 4.43 | 4.42 | 4.44 | 4.43 | 4.42 | 4.40 | 4.41 | 4.44 | 4.43 | 4.43 | 4.42 | 4.42 | |
Setting water temperature | ºC | 50ºC(default) 28-60ºC(adjustable) | |||||||||||||
Rated hot water yields | L/H | 258 | 408 | 258 | 408 | 537 | 752.5 | 1075 | 1397.5 | 1612.5 | 1827.5 | 2257.5 | 2687.5 | 3547.5 | |
Power supply | 1N 220V/50Hz (Special power supply for option) |
3N 380V/50Hz (Special power supply for option) |
|||||||||||||
Compressor | Type | Hermetic scroll type | |||||||||||||
Start mode | Directly start(Soft start for option) | ||||||||||||||
Quantity | Unit | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 4 | 2 | 3 | 3 | 4 | |
Water Side | Heat exchanger | Shell & coil(tube) heat exchanger | |||||||||||||
Water flow | m3/h | 2.1 | 3.3 | 2.1 | 3.3 | 4.3 | 6.0 | 8.6 | 11.2 | 12.9 | 14.6 | 18.1 | 21.5 | 28.4 | |
Water pressure drop | kPa | ≤45 | ≤53 | ≤45 | ≤53 | ≤55 | ≤60 | ≤60 | ≤60 | ≤65 | ≤68 | ≤70 | ≤70 | ≤75 | |
Connection size | DN | DN25 | DN25 | DN25 | DN25 | DN25 | DN32 | DN32 | DN50 | DN50 | DN50 | DN50 | DN65 | DN80 | |
Air Side | Exchanger | Finned tube heat exchanger | |||||||||||||
Rated Air flow | m3/h | 3500 | 6320 | 3500 | 6320 | 7500 | 12500 | 14800 | 14800 | 26000 | 26000 | 39000 | 39000 | 52000 | |
Rated output power of fan motor | W | 120 | 250 | 120 | 250 | 370 | 550 | 750 | 750 | 1100 | 1100 | 1500 | 1500 | 2200 | |
Protections | 1. High pressure and low pressure protection, 2. Anti-freezing protection, 3. High temperature protection, 4. Too big of the water temperature difference for outlet and inlet protection, 5. Overload protection, 6. Lack phase protection, 7. Reverse phase protection, etc.. |
||||||||||||||
Refrigerant | Throttle type | Electronic expansion valve | |||||||||||||
Type | R410a | ||||||||||||||
Quantity | kg | 1.9 | 2.8 | 1.9 | 2.8 | 4.1 | 2.8×2 | 4.1×2 | 5.2×2 | 3.2×4 | 7.6×2 | 6.2×3 | 7.6×3 | 7.6×4 | |
Noise | DB(A) | ≤55 | ≤63 | ≤55 | ≤63 | ≤65 | ≤65 | ≤66 | ≤68 | ≤70 | ≤72 | ≤73 | ≤75 | ≤78 | |
Dimension | mm | 710x710x1100 | 990x990x1800 | 1000x2050x1850 | 2000x2050x1850 | ||||||||||
Wooden case package dimensions(LxWxH) | mm | 766x766x1146 | 1046x1046x1968 | 1056x2106x2018 | 2056x2106x2018 | ||||||||||
Net weight | kg | 108 | 135 | 108 | 135 | 165 | 340 | 400 | 485 | 605 | 660 | 835 | 840 | 1230 | |
Gross weight | kg | 123 | 150 | 123 | 150 | 180 | 370 | 430 | 515 | 640 | 695 | 870 | 875 | 1265 | |
Testing conditions: | |||||||||||||||
1. Application side initial water temperature: 15ºC, end temperature 55ºC, max. temperature 60ºC. | |||||||||||||||
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC. | |||||||||||||||
The above parameters are based on Refrigearnt R410a, for parameters based on other refrigerant please contact us. | |||||||||||||||
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label, or refer to us for any information. Our company keeps the right to interpret. |